RSICC CODE PACKAGE
CCC-522
1.
NAME AND TITLE
VARSKIN 3: Computer Code
System for Assessing Skin Dose from Skin Contamination, Version 2.2.0.
2.
CONTRIBUTOR
Colorado State University, Fort
Collins, Colorado.
3.
CODING LANGUAGE AND COMPUTER
Fortran and Visual Basic; Pentium
(C00522PC58604).
4.
NATURE OF PROBLEM SOLVED
VARSKIN 3 calculates the radiation dose (gamma and beta)
to skin from radioactive contamination of skin or protective clothing. It is a
modification of VARSKIN MOD 2 and was designed to operate in a Windows®
environment. The new code is
significantly easier to learn and use than the previous release and includes
numerous corrections and enhancements that are noted in the User Manual.
Backscatter correction and gamma dose models were upgraded. The default area for
skin dose calculations was changed to 10 cm2 to conform to recent
regulatory guidance. The input data file for VARSKIN Mod 2 was modified to
reflect current physical data, to include the contribution to dose from internal
conversion and Auger electrons, and to reflect a
correction for low-energy electrons. In addition, the computer code SADDE
(Scaled Absorbed Dose Distribution Evaluator) Mod 2, was incorporated into Varskin 3, thus eliminating the need for additional input
from the user.
VARSKIN3 calculates the dose to 10 cm2 as a
default for comparison to the 50 rad limit and also
contains the capability of calculating the dose to 1 cm2 to evaluate
an exposure against the eye dose limit.
The dose is computed at any depth in skin or in a volume of skin from
point, disk, cylindrical, spherical, and slab (rectangular) sources. Doses from multiple sources can be
computed.
5.
METHOD OF SOLUTION
VARSKIN 3 uses improved algorithms for calculating skin
dose that take advantage of the increased power of modern personal computers
that improve the overall accuracy of the calculations. Source density is reset
to 0.001 g/cm3 when point and 2-D models are used for
calculations. The backscatter
correction model has been expanded to include 3-D sources and is applied
regardless of the dose-averaging area.
The minimum distance between the source and target was reduced from 0.27
μm to a value of 0.01 μm. Sixty
radial dose calculation points are used on the target area instead of 26 points
used in VARSKIN Mod 2. Once the 60-point distribution is calculated, the
distribution is evaluated at 10,000 points to increase the reliability of the
calculation. VARSKIN 3 evaluates the dose at 50 depths for volume averages
instead of 20 points. Once the 50 point distribution is calculated, the
distribution is evaluated over 10,000 points to increase the accuracy and
eliminate oscillating results. VARSKIN 3 calculates the backscatter correction
factor at each of the 50 depths in the volume averaged dose distribution. In VARSKIN 3, the capability of adding
multiple radionuclides was eliminated and a more
accurate method of creating library files was incorporated. An improved gamma
dose model was incorporated into VARSKIN 3 that calculates the gamma dose to any
area smaller than 10 cm2.
BETADATA.DAT is no longer used as the input file for VARSKIN 3. Each user
builds a library that contains only the radionuclides
of interest to that user. The new data files contain physical data for the
average energy, maximum energy, and yield based on data generated by the
computer code NUCDECAY (Oak Ridge National Laboratory, 1995, distributed by
RSICC as DLC-172), which uses data published in ICRP 38 (1983). Further
information in the library files includes data for gamma dose calculations and
contribution from internal conversion and Auger electrons.
6.
RESTRICTIONS OR LIMITATIONS
See the User Manual for details on
restrictions.
7.
TYPICAL RUNNING TIME
Run times for VARSKIN 3 vary from a few seconds to
several minutes. The code is interactive.
8.
COMPUTER HARDWARE REQUIREMENTS
VARSKIN 3 was tested at RSICC on a Pentium IV running
Windows XP with Service Pack 2.0. It was also tested with Windows 2000 SP 4. A
graphics card is required.
9.
COMPUTER SOFTWARE REQUIREMENTS
VARSKIN 3 was developed under the Windows operating
system on personal computers. Microsoft Visual Basic 6 (for the user interface)
and Compaq Visual Fortran Version 6.6 compilers were
used to create the executables which are included in the package. In the Version
2.2.0 release, source files were added to the package; and on-line help was
implemented.
10.
REFERENCES
a:
Included in documentation:
J. S. Durham, "VARSKIN 3: A Computer Code for Assessing
Skin Dose from Skin Contamination," NUREG/CR Draft (November
2004).
b:
Background information:
R. J. Traub, W. D. Reece, R.
I. Scherpelz, and L. A. Sigalla, "Dose Calculation for
Contamination of the Skin Using the Computer Code VARSKIN," NUREG/CR-4418,
PNL-5610, Pacific Northwest Laboratory (August 1987).
J. W. Poston and D. M. Busche,
"Software Review: VARSKIN-MOD1," Health Physics 58(5),
665.
W. D. Reece, S. Miller, and J. Durham,
"SADDE (Scaled Absorbed Dose Distribution Evaluator)," NUREG/CR-5276, PNL-6761
(January 1989).
J. S. Durham, “Errata for NUREG/CR-5873, VARSKIN MOD 2
and SADDE MOD 2: Computer Codes for Assessing Skin Dose from Skin
Contamination,” Health Physics Society’s Newsletter, 10, 31-32 (October
1994).
J. S. Durham, “Further Errata for
NUREG/CR-5873, VARSKIN MOD 2 and SADDE MOD 2,” Health Physics Society’s
Newsletter, 12, 18 (December 1994).
11. CONTENTS OF
CODE PACKAGE
Included are the referenced document in 10a.and the
source code, executables and built-in data libraries. The package is transmitted
on a CD.
12. DATE OF
ABSTRACT
December 1987, revised February 1993, March 1995,
October 2004, November 2004.
KEYWORDS:
BETA-RAY; KERNEL; RADIOACTIVITY;
ENERGY DEPOSITION; MICROCOMPUTER