1. NAME AND TITLE
SWANLAKE: Cross Section Sensitivity Analysis Code System for One-Dimensional
Discrete Ordinates Calculations.
AUXILIARY ROUTINE
INTRIGUE II-L CALCOMP Plotting Package.
CCC-254/ANISN or other comparable code is needed for input data generation.
It is not included in this package.
2. CONTRIBUTOR
Oak Ridge National Laboratory, Oak Ridge, Tennessee.
3. CODING LANGUAGE AND COMPUTER
FORTRAN IV and Machine Language; IBM 360/91.
4. NATURE OF PROBLEM SOLVED
SWANLAKE determines the sensitivity of a calculated quantity or result to
microscopic cross section data utilized in the calculation.
5. METHOD OF SOLUTION
A particular sensitivity function, which represents an application of earlier
perturbation approaches, is determined for the cross sections which were
utilized in the discrete ordinates calculation.
6. RESTRICTIONS OR LIMITATIONS
The discrete ordinates calculations to be analyzed by this version of
SWANLAKE must be time-dependent and one-dimensional. The sensitivity function
only allows for energy downscatter, does not include the effects of fission
cross sections, and cannot evaluate the sensitivity of the calculated quantity
or response to the response function itself.
7. TYPICAL RUNNING TIME
The infinite air sample problem included in the code package required 2.5
minutes for the ANISN forward calculation, 2.5 minutes for the ANISN adjoint
calculation, and 1.8 minutes for the SWANLAKE calculation.
8. COMPUTER HARDWARE REQUIREMENTS
Designed for the IBM 360/91, SWANLAKE is also operable on the IBM 360/75. Maximum core requirement for the sample problems discussed in the code manual is 848K bytes, minimum size is 290 K bytes.
Auxiliary storage requirements, in addition to standard input and output
devices, are 2 scratch devices and 3 storage devices. If cross sections are not
read from cards, an additional tape or disk will be required, and if the CALCOMP
plotting routine included in the package is to be used, another tape unit is
required.
9. COMPUTER SOFTWARE REQUIREMENTS
A FORTRAN IV compiler is required. A CALCOMP plotting package, INTRIGUE-II
(PSR-54), is included in the SWANLAKE package.
10. REFERENCES
D. T. Ingersoll, "Availability of SWANLAKE," memo (October 1978).
D. E. Bartine, F. R. Mynatt, and E. Oblow, "SWANLAKE, A Computer Code Utilizing ANISN Transport Calculations for Cross Section Sensitivity Analysis," ORNL-TM-3809 (May 1973).
M. B. Emmett, "INTRIGUE-II: An IBM 360 Subroutine Package for Making Linear,
Logarithmic and Semilogarithmic Graphs Using the CALCOMP Plotter," ORNL-4664
(March 1971).
11. CONTENTS OF CODE PACKAGE
Included are the referenced documents and one (1.2MB) DOS diskette which
contains the source code and sample problem input and output.
12. DATE OF ABSTRACT
August 1975; reviewed February 1983.
KEYWORDS: NEUTRON; GAMMA-RAY; SENSITIVITY ANALYSIS; CROSS-SECTION ANALYSIS; ONE-DIMENSION