1. NAME AND TITLE
NJOY-UTIL-EIR: Utilities For the NJOY (6/83) Nuclear Data Processing System.
2. CONTRIBUTOR
Swiss Federal Institute for Reactor Research, Würenlingen, Switzerland,
through NEA Data Bank, Gif-sur-Yvette Cedex, France.
3. CODING LANGUAGE AND COMPUTER
Fortran IV; CDC CYBER 825.
4. NATURE OF PROBLEM SOLVED
NJOY-UTIL-EIR complements the NJOY (6/83) nuclear data processing system. The
eight modules in the system have the following functions: collapsing of
groupwise files, combining of ENDF/B formatted files, separation of one file,
plotting of cross sections or differences between two cross section files and
combining ACE cross section files.
5. METHOD OF SOLUTION
COLLGR was developed to collapse multigroup cross section GENDF data.
ECOMBR combines two ENDF, PENDF or GENDF binary cross section files given in either ENDF/B-IV or in ENDF/B-V format.
SEPR separates from a given PENDF, GENDF or ENDF/B file required materials and temperatures.
DICTR prints a list of available isotopes.
MANAGR copies ENDF, PENDF, or GENDF binary files and change their format from ENDF/B-IV to ENDF/B-V or vice versa.
EPLOTR (based on EVALPLOT (PSR-211) is designed to read evaluated data from the ENDF/B format and to plot the data.
CPLOTR (based on COMPLOT (PSR-259)) is designed to compare ENDF/B formatted data from two separate input tapes. Reactions are comparable if they have the same (ZA,MT). Results are presented in graphical form.
ACOMBR inserts or deletes cross section ACE files to or from the coded ACE
cross section library.
6. RESTRICTIONS OR LIMITATIONS
EPLOTR uses only the ENDF/B BCD format. For CPLOTR, cross sections must be
either in histogram or linearly interpolatable form.
7. TYPICAL RUNNING TIME
On a CDC 7600, it takes 6.2 minutes to plot the entire ENDL library in the
ENDF/B format (1132 plots, including 384 cross sections, 506 of angular
distributions, and 292 of energy distributions).
8. COMPUTER HARDWARE REQUIREMENTS
NJOY-UTIL-EIR runs on the CDC Cyber 825. The graphics uses the CALCOMP
plotter for the CDC EMOS system.
9. COMPUTER SOFTWARE REQUIREMENTS
The code was written in Fortran IV.
10. REFERENCE
a. Included in the documentation:
S. Pelloni, C. Higgs, and J. Stepanek, "The NJOY Nuclear Data Processing
System: The COLGR, ECOMBR, SEPR, DICTR, MANAGR, EPLOTR, CPLOTR, and ACOMBR
Modules," EIR-Bericht Nr. 566 (August 1985).
11. CONTENTS OF CODE PACKAGE
Included are the referenced document and one DS/HD (1.2 MB) 5.25 inch
diskette.
12. DATE OF ABSTRACT
December 1990.
KEYWORDS: CONVERSION; ENDF/B-V; ENDF FORMAT; GAMMA-RAY CROSS SECTION PROCESSING; NEUTRON CROSS SECTION PROCESSING; MULTIGROUP CROSS SECTION PROCESSING